Next: DISCO-FOCUS
Up: First leg - MCS
Previous: Standard procedures for the
- SEG-D input (two format codes had been used: 8048,8058)
- Re-sampling data at 4 ms
- Band-pass filter: 6-9-58-62.5 Hz
- Edit traces
- Hand Statics: -20 ms
- Load Geometry and CMP sorting
fold: 6 or 16 or 24 (100m,37.5m,25m distance between shots)
- Interactive Velocity Analysis
- NMO Correction and Stack
- Top mute
- Minimum phase predictive deconvolution:
decon operator length: 300 ms; prediction distance: 20 ms
- Band pass filter: time and space-variant Ormsby band-pass filter
- True Amplitude Recovery: basis for spherical spreading (1/dist)
- Trace Mixing:
trace mixing algorithm: weighted mix.
5 traces to mix over with trace weights 1,3,7,3,1
- Time Scaling: Automatic Gain Control
type of AGC scalar: normally 2000ms but sometimes 6000ms
- Trace plotting in a Oyo Geospace plotter: plotter device 24 inch, bytes per scan 1184
Figure 6:
BS98. MCS line BS20, stack.
|
2010-05-12